KNAUF W623 PDF

Plasterboard and prewall W – Plasterboard and prewalls – Details catalog – KNAUF – Manufacturers. W, W Gypsum Board Drywall Lining System is installed by applying single layer Knauf Gypsum Board with minimum thickness 9,5mm on the existing . Improvement Guide Knauf Wall Linings Thermal Insulation Improvement Guide W Knauf Independent Furring with CD Channels W Knauf Independent.

Author: Arashizuru Kazrarg
Country: Thailand
Language: English (Spanish)
Genre: Education
Published (Last): 24 April 2011
Pages: 358
PDF File Size: 18.99 Mb
ePub File Size: 9.30 Mb
ISBN: 849-6-85861-373-2
Downloads: 5795
Price: Free* [*Free Regsitration Required]
Uploader: Kazrazil

Where insulation is required within the wall lining void.

W System Knauf W Under good building practice, however, any deleterious deposits, such as mould, oil or grease, should be removed as a precaution. By continuing to browse the site you are agreeing to our use of cookies.

Plasterboard and prewall W – Knauf Gips KG – cad dwg architectural details – ARCHISPACE

W Gypsum Board Drywall Lining System is installed with DC stud and DU channel which are located separate from the wall and kknauf 12,5 mm double layer Gypsum Board and in between mineral wool for fulfilling thermal insulation and fire resistance requirements.

WC Cleaneo Drywall Lining System is installed on the existing wall with direct hanger, Ceiling C channel and Ceiling U channel with single layer Onauf according to the required area and single layer 12,5 mm Knauf Gypsum Board double layer where Cleaneo is not applied and in between mineral wool in order to fulfill the optimum sound absorption requirements. Data Sheet WC Cleaneo WC Cleaneo Drywall Lining System is mnauf on the existing wall with direct hanger, Ceiling C channel and Ceiling U channel with single layer Cleaneo according to the required area and single layer 12,5 mm Knauf Gypsum Board double layer where Cleaneo is not applied and in between mineral wool in order to fulfill the optimum sound absorption requirements.

  FAMILIA TRYPANOSOMATIDAE PDF

Pretreatment of the background is not required.

Do you have any questions? Where a variable stand-off clearance is required between lining and background of between 27 and mm. Data Sheet WC Cleaneo WC Cleaneo Drywall Lining System is installed with DC stud fixed from the back sides and DU channel which are located separate from the wall and with single layer Cleaneo according to the required area and single layer 12,5 mm Gypsum Board Double layer where Cleaneo is not applied and in between mineral wool in order to fulfill the optimum sound absorption requirements.

The system can be applied to the majority of all common building substrates. Data Sheet System Description Download W W Gypsum Board Drywall Lining System is installed on the existing wall with direct hanger, Ceiling C and U channels with single or double layer 12,5 mm Gypsum Board and in between mineral wool in order to fulfill the sound and thermal insulation requirements.

This site uses cookies so that we can provide you with the best user experience. Knauf Readygips can be applied as a skim coat to achieve a smooth plastered finish. The system can provide a variable stand-off from the background of between 27 and mm. Privacy and Cookie Policy. Where deep service runs are required to be accommodated within the lining void. BoxDubai – U. My leaflet Show entire leaflet. This makes it capable to override substantial irregularities in the background.

Knauf Wall Lining Systems

Knauf Wall Lining Systems. The lining void facilitates the introduction of thermal or acoustic insulation and provides containment for service runs.

  ALIMENTO BALANCEADO PARA CUYES PDF

Data Sheet W W Gypsum Board Drywall Lining System is installed with DC stud and DU channel knaut are located separate from the wall and with 12,5 mm double layer Gypsum Board and in between mineral wool for fulfilling thermal insulation and fire resistance requirements.

Knauf Linings can accommodate knaut of the range of Knauf Gypsum Boards, depending w23 the performance requirements. W Gypsum Board Drywall Lining System is installed with DC stud and DU channel which are located separate from the wall and with 12,5 mm single layer Knauf Gypsum Board and in between mineral wool for fulfilling thermal insulation and fire resistance requirements.

W Gypsum Board Drywall Lining System is installed on the existing wall with direct hanger, Ceiling C and U channels with single or double layer 12,5 mm Gypsum Board and in between mineral wool in order to fulfill the sound and thermal insulation requirements.

Where background is not aligned properly. WC Cleaneo Drywall Lining System is installed with DC stud fixed from the back sides and DU channel which are located knaf from the wall and with single layer Cleaneo according to the required area and single layer 12,5 mm Gypsum Board Double layer where Cleaneo is not applied and in between mineral wool in order to fulfill the optimum sound absorption requirements.

W Single Layer with Insulation.