Honeywell RMA On-Off Primary Burner Control: Hvac Controls: : Industrial & Scientific. Find great deals for Honeywell Rm a Rev D Burner Control RMA Shop with confidence on eBay!. The RMA by Honeywell is a microprocessor based integrated primary burner control for automatically fired gas, oil or combination fuel single burner.

Author: Gubei Meshakar
Country: Thailand
Language: English (Spanish)
Genre: Travel
Published (Last): 15 February 2012
Pages: 317
PDF File Size: 18.71 Mb
ePub File Size: 9.52 Mb
ISBN: 209-4-69250-134-9
Downloads: 98312
Price: Free* [*Free Regsitration Required]
Uploader: Kigakasa

If tolerances are not met in 4 minutes, a lockout will occur. Vast amounts of important information are stored in the relay module.

RMA,RMA,Honeywell,,FSG Control Auto Primary V Primary Co,Stromquist & Company

It depends on the length of the purge card timing. It is active in standby. This page location is: The power must be within certain tolerances for the control to remain on line. Every insurance organization and approval body in the U.

Wire the relay coil and thermostat contacts in series on the low voltage side of the transformer. Skip to main content. Product Code Quantity 1 2 3 4 5.

RMA Honeywell BURNER CONTROL

Pilot Honetwell intermittent Vibration 0. On the E and L, all terminal functions are the same. Does the SA display have any control of the relay functions?

Yes, but you will add 30 seconds to the pre-purge timing for each switch jumpered. If the circuit remains closed for the two minutes, the RMB and D will lockout. December 13, – 1: When replacing an RA that used a low voltage thermostat connected to T and T terminals for the old Q base, and it is inconvenient to change to a line voltage controller, a 24 VAC coil relay and transformer can be added.

  KORA VASKO POPA PDF

Please contact Customer Care for assistance. There are 50 HZ controls available. If JR3 is left intact, the control will recycle to the beginning of purge.

Mechanical relays are still used, but the coils and contacts are sealed to prevent dirt, dust, grease, or any contaminant from affecting them.

This means the relay is checking itself internally. Product Info Hooneywell Overview Microprocessor-based integrated primary burner control for automatically fired gas, oil or combination fuel single burner applications. Please enable scripts and reload this page. Yes, order part number Long enough to result in four complete air changes through the burner. Forgot User Name or Password?

RM7890A1015 Honeywell BURNER CONTROL

When using an M, many times honeyweell will be no L. You may be trying to access this site from a secured browser on the server. Microprocessor-based integrated primary burner control for automatically fired gas, oil or combination fuel single burner applications.

It depends on how relay jumper JR3 is configured. Also, on a call for heat, all the output terminals are momentarily turned into inputs for a load check.

  DIN 28131 PDF

Is this to attract attention that something is wrong? The burner will immediately shut down, and lockout will occur. The C also has a fixed pilot of 10 seconds. Turn off more accessible mode. Industrial Combustion Training Videos. They wire the same and functionally, are the same. They consist of a specific resistor. First, remember that cutting a jumper does not make the relay inoperative. A low fire start switch is used to prove the firing rate valve motor is in the low fire position before and during ignition.

The RMA and C do not have this feature. Can I jumper terminal G to L2? In the real world of burner service, the needed information is seldom known.

Turn on more accessible mode. The SA display does not have to be wired to the SA.

Request Our Free Catalog. Typically, it is a fuel valve proof of closure switch. What happens if the airflow switch does not close in the allocated time?